Appleton AGLCS Series: GRP Local Control Station & Switches
Application
- Providing local and motor control for hazardous areas in explosive gas Zone 1 and 2 or explosive dust Zone 21 and 22 environments.
- Applicable in wash down areas for indoor or outdoor appli- cation where water and dust ingress protection is required.
- Suitable for highly corrosive environment that has either chemical, moist or salt-water (marine outside type) in the surrounding area.
- Push buttons and selector switches provides circuit control and/or selection which are used in conjunction with con- tactors or magnetic starters for remote control of motors in hazardous locations.
- Pilot lights gives visual assurance that an electrical function is being performed at a remote or hazardous location.
- For use in different field application such as
- Oil and Gas
- Petrochemical
- Pulp and Paper
- Food & Beverage Processing
- Water and Wastewater Treatment
- Power Generation
- Pharmaceutical Industry
- Silos and Other Industrial Process Facilities.
Features
- Static resistant black glass reinforced polyester enclosure.
- The high IP rating allows the enclosure to be installed in either indoor or outdoor environments.
- Designed for application with voltage ratings up to 5,500V AC and rated current up to 1,500A.
- Multiple enclosure size for different control, indicator or selector configurations.
- Utilizes factory sealed (Ex e or de) operators which includes push buttons, illuminated push buttons, ammeter, selector switches, control and load break switches, contact blocks, LED pilot lights, and terminal blocks.
- Using high intensity LED pilot lights which has a lifetime of 100,000 hours, it can be used for inputs with 12V AC to 254V AC 50/60Hz or 12V DC to 60V DC
- Operators and contact blocks are properly spaced to have easy and ample space for wiring.
- Up to 3 contact blocks per actuator can be used.
- Contact block technical data:
- IEC rated operating voltage (Ue): 500V AC – 110V DC
- IEC switching capacity:
- AC12: 16 Amp/400V AC
- AC14: 10 Amp/400V AC
- AC15: 6 Amp/500V AC
- DC13: 2 Amp/24V DC and 1 Amp/110V DC
- Selector switch technical data:
- IEC rated operating voltage: 690V AC
- IEC rated operating current: maximum 16 Amp
- IEC switching capacity:
- AC1: 16 Amp/690V AC
- AC15: 16 Amp/415V AC
- AC3: 8 Amp/500V AC
- AC3: 4 Amp/690V AC
- AC3: 16 Amp/690V AC
- DC1: 10 Amp/24V DC DC1: 6 Amp/60V DC
- DC1: 6 Amp/110V DC (2 contacts wired in series)
- DC1: 6 Amp/220V DC (3 contacts in series)
- NEMA switching capacity: A600: 10 Amp/600V AC
- Components are DIN rail mounted which is held securely in place during operation and easily removed for service.
- Captive, corrosion resistant stainless steel cover screws.
- Multiple wiring or cable termination with a wide selection of cable glands and union adapters for the entries at 4 sides of the enclosure.
- Contact block technical data:
Related products
Classic wooden chair
ECOM Intrinsically safe smartphone: The new Smart-Ex® 02 for Zone 2 and Division 2
HOFFMAN Corrosion Inhibitor
Use Corrosion Inhibitors to protect electronic components inside the enclosure against corrosion. It is simple and economical to use; no surface preparation is required and puts protected equipment to use immediately without degreasing or coating removal. Each inhibitor contains a special chemical combination that vaporizes and condenses on all surfaces in an enclosed area. Vapors will redeposit as needed in the event of condensation of moisture on surfaces. These vapors reach every part of an enclosure, protecting all interior components. They do not interfere with electrical, optical or mechanical surface properties. Protection is effective even in salt-water atmospheres. The AHCI5E and AHCI10E emitters have additional red-metal inhibitors for further protection. The normal useful life-span of Hoffman corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since Corrosion Inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors. Each Corrosion Inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). Hoffman corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and/or (3) cabinet length divided by depth is greater than four.
The normal useful life-span of HOFFMAN corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since HOFFMAN corrosion inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors.
Each nVent HOFFMAN corrosion inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). HOFFMAN corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and/or (3) cabinet length divided by depth is greater than four.
Reviews
There are no reviews yet.