APPLETON TMC2100118NB TMC2 Cable Gland NI/BR 100NPT

Product Dimentions 5 x 5 x 9 inches; 0.01 Ounces Item Model Number CJPPB1775GMTDOW Date First Available June 2, 2014

Appleton TMC2050075A Cable Gland Connector

Brand Appleton® Cable Openings 1/2 to 3/4, 1/2 to 3/4 in Angle 360, 360 deg Connection Type NPT Dimension 1.2

Appleton® TMCX050A Explosion Proof Cable Gland Connector

Brand Appleton® Cable Openings 0.55 to 0.79 in Cable Type MC/Teck Connection Type NPT Dimension 2.79 in L Manufacturer Emerson

APPLETON ELECTRIC Reducing Bushing

Haz Loc: Aluminum, 1/2 in_3/4 in Trade Size These reducing bushings adapt narrow, threaded heavy-wall RMC and medium-wall IMC metal

APPLETON Fixture Hanger Bracket and Accessories

Fixture Hanger Brackets are used to mount fixtures directly to ceiling or wall separately from the conduit system. Safety Supports are available in a complete unit with two hooks and one rigid support for use on the dummy side of a lighting fixture. Locking Couplings prevent fixture stems from movement.

APPLETON Round Tapered Steel Poles

Round Tapered Steel Poles are used to mount single or multiple luminaires to heights from 6.1 to 11.9 m (20 to 39 ft).

APPLETON Hinged Steel Poles

Hinged Steel Poles are used to mount single or multiple luminaires to heights from 6.1 to 9.1 m (20 to 35 ft). Hinged design allows easy servicing of luminaires at shoulder height.

APPLETON PCD2 Series Hazardous Location Photocontrol

PCD2 Series Hazardous Location Photocontrol provides automatic dusk-to-dawn lighting control in Class I, Division 2 locations. This encapsulated photocontrol is ideal for remote mounting in an FS box.

APPLETON PC Series Industrial Location Photocontrol

PC Series Industrial Location Photocontrol provides automatic dusk-to-dawn lighting control in non-hazardous locations It is a durable polycarbonate housing with a clear UV stabilized window ultrasonically welded in place. It is ideal for remote mounting in an FS box.

APPLETON EFKB Series Photocontrol

EFKB Series Photocontrol provides automatic dusk-to-dawn lighting control. The FD Series factory sealed single gang cast device boxes confines any arcing of the device within the enclosure, preventing ignition of ignitable atmospheres during operation. This encapsulated device is ideal for remote mounting.

HOFFMAN Corrosion Inhibitor

Use Corrosion Inhibitors to protect electronic components inside the enclosure against corrosion. It is simple and economical to use; no surface preparation is required and puts protected equipment to use immediately without degreasing or coating removal. Each inhibitor contains a special chemical combination that vaporizes and condenses on all surfaces in an enclosed area. Vapors will redeposit as needed in the event of condensation of moisture on surfaces. These vapors reach every part of an enclosure, protecting all interior components. They do not interfere with electrical, optical or mechanical surface properties. Protection is effective even in salt-water atmospheres. The AHCI5E and AHCI10E emitters have additional red-metal inhibitors for further protection. The normal useful life-span of Hoffman corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since Corrosion Inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors. Each Corrosion Inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). Hoffman corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and/or (3) cabinet length divided by depth is greater than four.

The normal useful life-span of HOFFMAN corrosion inhibitors is in excess of one year. However, inhibitor life expectancy is shortened by approximately 25 percent when exposed to temperatures above 104 F (40 C). This product is not recommended for use where temperature exceeds 199 F. Since HOFFMAN corrosion inhibitors are vapor-phase protective, all surfaces to be protected should be accessible to the vapors. The maximum distance the vapors can travel is approximately 1.50 ft. (.46 m). Protection of long, narrow enclosures can be achieved with tape or multiple inhibitors.

Each nVent HOFFMAN corrosion inhibitor is individually packaged in a resealable bag for maximum effectiveness at the time of usage. Corrosion inhibitors should be stored at temperatures not exceeding 120 F (45 C ). HOFFMAN corrosion inhibitors are not returnable. When determining the proper corrosion inhibitor for your application, assume the enclosure volume to be protected is greater than calculated if (1) cabinet doors are opened frequently, (2) cabinet is located in an extremely corrosive area and/or (3) cabinet length divided by depth is greater than four.

HOFFMAN Hazardous Location Breather Drains

Hazardous Location Breather Drains prevent moisture build-up within hazardous approved enclosures while maintaining enclosure UL Type rating. Drains are to be used when an enclosure is subject to fluctuations in temperature which can lead to the formation of condensation and a subsequent moisture build-up. These drains allow air within an enclosure to breathe with the surrounding atmosphere, preventing condensation and any potential damage to electrical equipment.

HOFFMAN Hazardous Location Heaters

Designed for hazardous locations where electronic components require protection from cold freezing temperatures, condensation and corrosion.